With SmartMedia version 2.6, the CDR processing has improved substantially, including various methods to protect against loss of CDR records. Here is a detailed explanation of the functionalities.

Contents

  • 1 CDR Redundancy
    • 1.1 Radius redundancy
    • 1.2 Radius and Text CDR
    • 1.3 Text CDR fallback
    • 1.4 Text CDR on Redundant servers (CDRs on both servers)
  • 2 How does it work?
    • 2.1 Request timeout
    • 2.2 Record queue full
    • 2.3 Text CDR Fallback

CDR Redundancy

Radius redundancy

More than one radius server can be configured. When a server starts responding, the RADIUS client will flag this server as 'online'. When a server is flagged as 'online' and there are no other 'online' servers at that time, the server is elected as 'current' (primary). All new CDR records will be sent to the primary, until it no longer responds. This list of Radius servers can be configured here:Configuring Radius

With version 2.7, SmartMedia fully supports redundancy on Radius authentication and accounting. See below link to know how it works:

Radius and Text CDR

This will send records to the Radius servers list and will also store it in Text CDR.

Text CDR fallback

This functions will only be used if there are no Radius servers 'online', or if the records queue is full. Otherwise, it works the same way as Text CDR.

Text CDR on Redundant servers (CDRs on both servers)

If you are using a SN10300, both Control Hosts can log Text CDRs locally. Text CDRs are not copied between hosts, therefore it is necessary to gather the CDRs from both hosts.

 

How does it work?

There are two cases where the RADIUS client will consider that a CDR record couldn't be sent:

Request timeout

When a CDR record is received by the RADIUS client and the number of concurrent records is not reached, it is assigned to the server which is considered 'current' (primary) at the time. It might be a server that is currently offline. A request is first sent. If it times out (according to the configured timeout for that server), the request is sent again (up to the number of configured Retransmissions). If all the retries timed out, the server is flagged as 'offline', a new 'current' (primary) server is elected and the record is discarded (that is reflected in the "Acct unanswered record cnt" status item).

Record queue full

When the number of records reach the "maximum accounting queued records" (default 12,000) the records will be discarded. This is shown in the "Acct overflow record cnt" status item.

Text CDR Fallback

In both cases, if text CDR fallback is configured, it will be forwarded to the text CDR module. Otherwise, the record is lost forever. There is no exception to that procedure. Even if all RADIUS servers are considered offline at some point, all CDR records will still be sent to all RADIUS servers, regardless if text CDR fallback is enabled.

User Rating
This answer was helpful This answer was not helpful (8783 vote(s)) 
User Comments  Add a Comment )

 
 
Products
Unified Communications
> VoIP Adapters
> Fax Adapters
> VoIP Gateways
> VoIP Routers
> VoIP IADs - Integrated Access Devices
> Enterprise Session Border Controllers
> Media Gateways
> SS7 Gateways
> Secure End Points (SIP Phones)
> VoIP Public Address & Mass Notification
Software and Cloud
> Virtual SBC | Virtualized SBC
> Virtual Access Router
> VPN Server
> IPv6 IPv4 Converter
> Intelligent Edge Orchestration
> NFV & SDN
Networking & Access
> Ethernet Extenders
> Industrial Switches
> Industrial Ethernet
> Unmanaged Industrial Ethernet Switches
> Managed Industrial Ethernet Switches
> Industrial PoE Switches
> PoE Extenders
> Industrial Network Solutions
> xDSL Products | DSL Modems, DSL VoIP, DSL Router Modems
> Routers
> Dial-Up Access

Sunset Products
 
Datacom Industrial Connectivity
> Industrial PoE Products
> Ethernet Over Fiber
> Line Drivers / Short Range Modems
> Wireline Analog Modems
> Pro AV Live & Media Broadcast Systems
> Fiber Serial DataCom (RS-232/422/530/188C)
> Fiber Telecom (T1/E1/PRI, Analog & ISDN)
> Multiplexers & Sharing Devices
> SFP (Small Form Pluggable) Modules and Kits
> Fiber Alarming, Notification, Relay & Control
> Other Network Extenders
> Defense/Security Fiber Communications
> Baluns
> Surge Protectors & Opto-Isolators
> DataTaps, Testers, Adapters, Rack Kits
> Interface Converters
> Fiber Rack & Enclosure Systems
> Fiber Repeaters & Wavelength Division Multiplexers (WDM)
> Waveguide RF Filters
Media Transport
> Artel Racks & Chassis Infrastructure
> Video Over IP Transport
> Video Over Fiber Transport
> Video, Audio & Data Over Fiber Transport
> Video & Audio Over Fiber Transport
> Ethernet Over Fiber Transport
> Serial DataComm Over Fiber Transport
> Video, Fiber Testers & Splitters
> Wave Division Multiplexers
> Ethernet Switches
> SFP Modules and Kits
 
Sales: [email protected] / +1 301 975 1000
Support: [email protected] / +1 301 975 1007
Join Our Email List
Have Us Contact You
or
Login Connect With Us
X Linkedin Facebook Youtube
 
     Patton LLC Copyright © 2025 All Rights Reserved.

|  Sitemap  |   Legal  |   Privacy Policy  |   Disclaimer  |    X  Facebook  YouTube  LinkedIn  RSS